Gas Turbine Genset
Gas Turbine Genset

Product Overview

Power2Go JT6 is a 6MW mobile gas turbine gensets independently developed by Jereh, featuring a complete Siemens Energy SGT-A05 turbine system. Designed for rapid deployment, it can be installed within 2 hours. The unit offers high integration, adaptability, stability, and ease of use. Ideal for short-term, mid-scale power needs in applications such as oilfield fracturing, microgrids, grid peaking, urban emergency power, and data center.

JT6
Product Model
JT6
  • JT6
Modular Design

Highly integrated design, with benefits of space-efficiency, easy to transport, fast deployment within 8 hours and high scalability to meet any power demands. 

High Reliability

Suited for high-power load fluctuations with excellent load acceptance and rejection performance. Dynamic response characteristics far exceed reciprocating generator sets.

Low Noise

Noise levels as low as 85 dBA, suitable for data centers and emergency power with low-noise requirements.

Multi-Mode and Grid Parellel

Supports hybrid power and grid-parallel modes, compatible with various existing generator sets. 

Strong Adaptability

Excellent fast response to power fluctuations, ensuring stable operation under large load changes.

High Expandability

Can be combined with other mobile generators, distribution, substation, energy storage, and integrated control devices to meet sophisticated power needs. 

Modular Design
High Reliability
Low Noise
Multi-Mode and Grid Parellel
Strong Adaptability
High Expandability
Specifications


ModelJT6
Power4.2 MW5.5 MW5.8 MW
Fuel TypeNatural Gas/Liquid Fuel/Dual-Fuel/Other Fuels
Efficiency29.70%32.10%33.10%
Heat Rate12,130 kJ/kWh11,202 kJ/kWh10,889 kJ/kWh
Voltage13.8/11 kV
Frequency60/50 Hz
NOx Emission≤ 25 ppmv 15%O2(DLE)
DimensionTruck~12,000×2,550×4,000 mm~13,600×2,550×4,000 mm
Trailer~13,700×2,550×4,000 mm——
WeightTruck~32,000 kg~54,500 kg
Trailer~40,000 kg——



Note:

1) The generated power is based on ISO condition, with gas fuel LHV 47.5 MJ/kg.

2) The International Organization for Standardization(ISO) has defined the following standard conditions:

 · Ambient Temperature:15℃ . Barometric Pressure:101.3 kPa.

 · Relative Humidity:60%. Inlet Exhaust Losses:None.

3) For detailed information, please consult Jereh's engineers.